What was found
INSPECTION TYPE:C, WHILE WORKING CARD 973519, FOUND CORROSION AND GOUGE ON STRINGER SPLICE BS 1000, STR 29R, RBL 6, WL 148. REMOVED AND REPLACED STR SPLICE BS 1000 STR 29R, RBL 6, WL148, WITH NEW STR SPLICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C, WHILE WORKING CARD 973519, FOUND CORROSION AND GOUGE ON STRINGER SPLICE BS 1000, STR 29R, RBL 6, WL 148. REMOVED AND REPLACED STR SPLICE BS 1000 STR 29R, RBL 6, WL148, WITH NEW STR SPLICE.