What was found
INSPECTION TYPE:C, CORROSION (C53-111-03.00-01) ON BONDED DOUBLER ON VERTICAL WEB OF HORIZONTAL WALKWAY BS 309. REMOVED DAMAGED BONDED DOUBLER, FABRICATED NEW BONDED DOUBLER AND INSTALLED IAW SRM 51-10-3, 51-10-6, 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C, CORROSION (C53-111-03.00-01) ON BONDED DOUBLER ON VERTICAL WEB OF HORIZONTAL WALKWAY BS 309. REMOVED DAMAGED BONDED DOUBLER, FABRICATED NEW BONDED DOUBLER AND INSTALLED IAW SRM 51-10-3, 51-10-6, 51-30-2.