What was found
INSPECTION TYPE:SI, FRAME IS CRACKED AROUND FASTENER HOLE AT BS 360 LBL 68, WL 303 JUST ABOVE STR 8. DAMAGE WAS OUT OF LIMITS. CUT OUT DAMAGE AREA 2.0' X 2.4 X .050, FABRICATED REPAIR DOUBLER OUT OF 7075.0. 50. SENT TO HEAT TREAT TO-T6 CONDITION AND INSTALLED REPAIR IAW SRM 51-40-3, SRM 51-30-2.