As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C DURING INSPECTION OF BS 825.95 L FRAME A CRACK WAS FOUND EMINATING FROM 3RD FASTENER HOLE ABOVE FLOOR FRAME BS 825.95 LT. REPAIRED IAW APPENDIX C OF EO B727-5310-5474- C & SMRO EO 99-30-002 UPS ENGINEERING FILE NR 5310-2172.