What was found
INSPECTION TYPE:SI, CORROSION ON STRINGER CLIP AT BS 1130, STR 27L. REMOVED CLIP, FABRICATED, HEAT TREATED AND INSTALLED STRINGER CLIP PER SRM 51-30-2, PG 8 & 9, MM 51-20-151.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:SI, CORROSION ON STRINGER CLIP AT BS 1130, STR 27L. REMOVED CLIP, FABRICATED, HEAT TREATED AND INSTALLED STRINGER CLIP PER SRM 51-30-2, PG 8 & 9, MM 51-20-151.