What was found
INSPECTION TYPE:SI, WHILE WORKING CUST CARD NR 997322 FOUND OUTBOARD TAB ON UPPER CHORD OF LOWER LONGITUDINAL BEAM CRACKED AND CORRODED RT SIDE. REMOVED AND REPLACED FABRICATED NEW REPLACEMENT CHORD AND INSTALLED PER IAW SRM 51-40-4.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:SI, WHILE WORKING CUST CARD NR 997322 FOUND OUTBOARD TAB ON UPPER CHORD OF LOWER LONGITUDINAL BEAM CRACKED AND CORRODED RT SIDE. REMOVED AND REPLACED FABRICATED NEW REPLACEMENT CHORD AND INSTALLED PER IAW SRM 51-40-4.