What was found
INSPECTION TYPE:C NOSE WHEEL WELL RIGHT SIDEWALL PRESSURE WEB CRACKED AT BS235.8, WL17 0. (JUST BELOW PRESSURE PANEL) CRACK VERIFIED PER NDT PART 6, 51-00-00 HFEC. STOP DRILLED CRACKS. T RIMMED OUT DAMAGED AREA. INSTALLED REPAIR ON RIGHT PRESSURE WEB BS23 5.8, WL170 IAW B727 SRM 51-40-2 FIG 1 MATERIAL USED 2024-T3, 0.050, 16 BY 9.