What was found
INSPECTION TYPE:SI, FWD CARGO BAY FRAME UPPER FLANGE PUNCTURED BS 680 LBL 23 WL 148.5. CUT OUT DAMAGED AREA 1 X 3 ON FRAME CROWN AT BS 680 LBL 23 WL 148.5, FABRICATED REPAIR DOUBLER, HEAT TREATED & INSTALLED ALL WORK ACCOMPLISHED IAW SRM 53-10-1, SRM 51-30-2, MM 51-20-21 AND MM 50-21-151 AND SRM 51-40-3.