What was found
INSPECTION TYPE-C2, CRACKED RIB JUST FWD OF THE TAIL CONE ACCESS PANEL 62, RT SIDE FS AREA 1910. FABRICATED DOUBLER IAW DC-8 SRM 53-2-0, STOP DRILLED CRACK IAW 53-2- 0, LOCATED AND DRILLED DOUBLER IAW DC-8 SRM 52-3-2, ALODINED AND PRIMED DOUBLER IAW DC-8 SRM 51-1-18, INSTALLED DOUBLER IAW DC-8 SRM 51-1-20 D.