INSPECTION TYPE:C2 CABIN AFT STA 1700 CANTER FRAME CORRODED AND CORROSION BETWEEN VERTICAL ATTACH PLATE L-36. CUT OUT CORRDED FRAME SECTION, VERTICAL ATTACH OUT OF LIMITS IAW DC8 SRM 53-2-0. FABRICATED NEW REPAIR ANGLE AND VERTICAL ATTACH PLATE AND SHIMS IAW REO 06339. ALODINED AND PRIMED IAW DC8 SRM 51-1-8. INSTALLED FRAME REPAIR AND VERTICAL PLATE IAW REO-06339 DC8 SRM 51-1-20D, 51-3-0, 51-1-8.