What was found
INSPECTION TYPE-C1, FLOOR ATTACH SUPPORT ANGLE IS CRACKED AT FS 1230 AFT OF TORQUE BOX AT LONG 36. CUT OUT DAMAGE, FABRICATED REPAIR ANGLE, ALODINED AND PRIMED IAW DC-8 SRM 51-1-8 AND REPAIR ANGLE IAW DC-8 SRM 53-2-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE-C1, FLOOR ATTACH SUPPORT ANGLE IS CRACKED AT FS 1230 AFT OF TORQUE BOX AT LONG 36. CUT OUT DAMAGE, FABRICATED REPAIR ANGLE, ALODINED AND PRIMED IAW DC-8 SRM 51-1-8 AND REPAIR ANGLE IAW DC-8 SRM 53-2-0.