What was found
INSPECTION TYPE-C/CK, INTERCOSTAL END FITTING AT STA 857 LONGERON 19L IS CRACKED. REMOVED CRACKED END FITTING IAW DC8 SRM 51-1-20D. MATERIAL ID FOR NEW END FITTING 7075-T651 PLATE PO 265699 IAW DAC DWG 4750422. FABRICATED NEW END FITTING IAW DAC DWG 4750422, PERFORMED DYE-PENETRANT INSPECTION IAW MIL-S-271F, ALODINED AND PRIMED IAW DC8 SRM 51-1-8, INSTALLED NEW END FITTING DC8 SRM 51-1-20D.