As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:SV, FUSELAGE STATION 1660 L34L FRAME SPLICE CRACKED. REPAIRED IAW REO 06455 REPLACED DAMAGED FRAME SEGMENT AT FUSELAGE STATION 1660 BETWEEN L27L AND RIGHT PER DAC 564024209 FIG 1 AND REPLACED CLIP 5640242-65 PER DWG AND 5615374DW USING 7075T6 ALUMINUM SHEET. UPS REPAIR AUTHORIZATION DC8-53-2578