What was found
INSPECTION TYPE:C2 LONG 24 RT UPPER FITTING AT FS 940 HAS CORROSION AT BOTTOM ATTACHMENT HOLES. REMOVED CORRODED FITTING, LOCATE NEW FITTING DRILL REAMED EXISTING HOLES IN FITTING IAW DC-8 SRM 51-3-2 AND INSTALLED IAW DC-8 SRM 51-1 -20D,CPCP.