What was found
INSPECTION TYPE:C2 AFT CARGO PIT STA 1300 6 EA FLOORBOARD SPLICES CORRODED X-38 TO X-20 FABBED AND INSTALLED NEW SPLICES IAW DC8 SRM 58-1-20 AND DC8 SRM 53-2-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C2 AFT CARGO PIT STA 1300 6 EA FLOORBOARD SPLICES CORRODED X-38 TO X-20 FABBED AND INSTALLED NEW SPLICES IAW DC8 SRM 58-1-20 AND DC8 SRM 53-2-3.