What was found
INSPECTION TYPE:C3, CORROSION ON AFT PRESS BULKHEAD FLOORBOARD SUPPORT ANGLE ABOVE LONG 32R. EXFOLIATED BEYOND LIMITS IAW DC8 SRM 53-2-0. FABBED NEW ANGLE IAW DWR NR 5753522. LOCATED, DRILLED AND DEBURRED NEW ANGLE, OK TO TREAT IAW DC8 SRM 51-3-2.