What was found
INSPECTION TYPE:C1 CORROSION ON AND AROUND T-ANGLE AND FASTENERS AT STA 70 BULKHEAD, RBL 28. REMOVED BOLTS IAW DC8 SRM 51-3-0. REMOVED CORROSION IAW DC8 SRM 51- 1-8, OUT OF LIMITS IAW DC8 SRM 53-2-0. RECEIVED ANGLE P/N NR 2615487-1 PO NR 304895. REMOVED CORROSION AROUND L-ANGLE, WITHIN LIMITS. LOCATED, DRILLED AND DEBURRED ANGLE IAW DC8 SRM 51-1-24. INSTALLED ANGLE IAW DC8 SRM 51-3-0.