What was found
INSPECTION TYPE:C1 STA 1580 R/S 26 ABOVE CUSP FRAME AND GUSSETT HAS DRILL DAMAGE. REMOVED DAMAGED GUSSETT AND FASTENER IAW DC8 SRM 51-21-1. REMOVED DAMAGE FROM FRAME IAW REO 06735. FABBED AND INSTALLED NEW GUSSET AND REPAIR ANGLE IAW DAC DWG 9751061, REO 06735, AND DC8 SRM 51-1-20D AND 51-1-21.