What was found
INSPECTION TYPE:C1, MAIN CABIN STA 1480 L3R TO L4R FRAME FWD FACE CORRODED. REMOVED CORROSION, FRAME FOUND TO BE OUT OF LIMITS. FABBED SPLICES IAW DC8 SRM 53-2-0, HEAT TREAT FOR T-6 CONDITION. GEN AND REC'D RFTS NR 836UP-24-20191 W/REO 06760, MAT ID S2537716-1400 7075-0 EXT PO NR 28567 8. LOCATED, REAMED, INSTALLED FRAME SEGMENTS AND SPLICES IAW DC8 SRM 51-1-24, 51-1-20D AND REO 06760.