What was found
INSPECTION TYPE:N/A, FUSELAGE NOSE SECTION, INTERM, REPAIR EO DC8 5300-11498A TO INCLUDE REMOVAL OF NOSE LANDING GEAR DOORS, BOTH PAC'S INOP (REF DEFERRAL M- 177745) RT PNEUMATIC PRESSURE INDICATION INOP (REF DEFERRAL M-177744 ) REF INCIDENT NUMBER RS99-288. COMPLIED WITH REPAIRS REF TIMCO REO NR'S 06734, 06743, 06756, 06765, 06767 REV B, 06776, 06778, 06791, 06797 REV B, 06800, 06802 REV A, 0 6820.