What was found
PIT - STATION 160 A/C CENTERLINE RIGHT FLOOR SUPPORT HAS 2 INCH BY 36 INCH CORROSION. LEVEL 1. MANUFACTURE NEW SUPPORT AND INSTALLED. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - STATION 160 A/C CENTERLINE RIGHT FLOOR SUPPORT HAS 2 INCH BY 36 INCH CORROSION. LEVEL 1. MANUFACTURE NEW SUPPORT AND INSTALLED. (M)