What was found
PIT - STA 917 A/C CENTERLINE. BEAM CAP HAD 1 INCH BY 2 INCH CHAFE MARK. KEEL BEEM FOUND CRACKED AT BS 917. BLENDED OUT WEAR MARKS AND INSTALLED .025 INCH SS WEAR STRIP PER SRM 53-05 FIG 20 PAGE 30A. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - STA 917 A/C CENTERLINE. BEAM CAP HAD 1 INCH BY 2 INCH CHAFE MARK. KEEL BEEM FOUND CRACKED AT BS 917. BLENDED OUT WEAR MARKS AND INSTALLED .025 INCH SS WEAR STRIP PER SRM 53-05 FIG 20 PAGE 30A. (X)