What was found
FOUND 2 INCH CRACK, STATION 767, STRINGER 18L. INSTALLED DOUBLER JUST AFT OF STATION 76D ON STRINGER 18L PER SRM 53-30-3 FIG B, PGS 11-12B SHTS 1-4. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND 2 INCH CRACK, STATION 767, STRINGER 18L. INSTALLED DOUBLER JUST AFT OF STATION 76D ON STRINGER 18L PER SRM 53-30-3 FIG B, PGS 11-12B SHTS 1-4. (M)