What was found
PIT - FOUND FRAME CRACKED AT STATION 787 STRINGER 8, 9 LEFT, .125 INCH TO .25 INCH. INSTALLED DOUBLER MADE FROM 7075-T6 .050 INCH THICK. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FRAME CRACKED AT STATION 787 STRINGER 8, 9 LEFT, .125 INCH TO .25 INCH. INSTALLED DOUBLER MADE FROM 7075-T6 .050 INCH THICK. (M)