What was found
CLT - FOUND .250 INCH BY .250 INCH OF CORROSION, BS 903 TO BS 1016, STRINGER 27L. INSTALLED DOUBLER AND EXTERNAL STRAP PER SRM 53-30-3 FIG 6 AND 17 AND SRM 53-10-3. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND .250 INCH BY .250 INCH OF CORROSION, BS 903 TO BS 1016, STRINGER 27L. INSTALLED DOUBLER AND EXTERNAL STRAP PER SRM 53-30-3 FIG 6 AND 17 AND SRM 53-10-3. (M)