What was found
CLT - FOUND CRACK IN STIFFENER 1.75 INCHES, STATION 178, LBL 5.5 LOWER AFT SIDE VERTICAL STIFFENER. INSTALLED DOUBLER PER TR 53-10-17 AND SRM 20-40-04. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND CRACK IN STIFFENER 1.75 INCHES, STATION 178, LBL 5.5 LOWER AFT SIDE VERTICAL STIFFENER. INSTALLED DOUBLER PER TR 53-10-17 AND SRM 20-40-04. (M)