What was found
CLT - FOUND CORROSION LEVEL 1, 1 INCH BY 2 INCH, STATION 500B ABOVE STRINGER 26R UNDER TRANSITION PANEL AND FRAME. INSTALLED REPAIR DOUBLER PER SRM 53-10-4. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND CORROSION LEVEL 1, 1 INCH BY 2 INCH, STATION 500B ABOVE STRINGER 26R UNDER TRANSITION PANEL AND FRAME. INSTALLED REPAIR DOUBLER PER SRM 53-10-4. (M)