What was found
CLT - FOUND CORROSION 8 INCHES BY 3 INCHES, AT STATION 968, STRINGER 25L FROM FORWARD EDGE OF STRINGER. SPLICED IN NEW STRINGER PER SRM 53-10-3. CORROSION LEVEL 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND CORROSION 8 INCHES BY 3 INCHES, AT STATION 968, STRINGER 25L FROM FORWARD EDGE OF STRINGER. SPLICED IN NEW STRINGER PER SRM 53-10-3. CORROSION LEVEL 2. (M)