What was found
PIT - FOUND CORROSION, 1 INCH BY 20 INCHES, FLOORBEAM UPPER CHORD, STATION 1309. CUT OUT CORRODED SECTION. INSTALLED NEW AND SPLICED PER EA 54092. CORROSION LEVEL 1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND CORROSION, 1 INCH BY 20 INCHES, FLOORBEAM UPPER CHORD, STATION 1309. CUT OUT CORRODED SECTION. INSTALLED NEW AND SPLICED PER EA 54092. CORROSION LEVEL 1. (M)