What was found
CLT - FOUND STIFFENER CORRODED 1 INCH BY 4 INCH, LOWER FRAME AFT STATION 1016 1 INCH RBL. INSTALLED REPAIR ANGLE AND FILLER PER SRM 51-70-11. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND STIFFENER CORRODED 1 INCH BY 4 INCH, LOWER FRAME AFT STATION 1016 1 INCH RBL. INSTALLED REPAIR ANGLE AND FILLER PER SRM 51-70-11. (M)