What was found
CLT - FOUND TWO CRACKS, .5 INCH AND .25 INCH, IN FLOOR SUPPORT STRAP BETWEEN STATION 780 AND 800 CENTER. FABRICATED NEW ANGLE PER SRM 53-00-51. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND TWO CRACKS, .5 INCH AND .25 INCH, IN FLOOR SUPPORT STRAP BETWEEN STATION 780 AND 800 CENTER. FABRICATED NEW ANGLE PER SRM 53-00-51. (M)