What was found
CLT - FOUND INTERCOSTAL 6 INCH BY 2 INCH, STATION 324 TO 345, R1 DOOR SILL. REPLACED INTERCOSTAL AT R1 DOOR PER SRM 57-10-00 AND 57-40-02. CORROSION LEVEL 1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND INTERCOSTAL 6 INCH BY 2 INCH, STATION 324 TO 345, R1 DOOR SILL. REPLACED INTERCOSTAL AT R1 DOOR PER SRM 57-10-00 AND 57-40-02. CORROSION LEVEL 1. (M)