What was found
CLT - FOUND FLOORBEAM CORRODED 1 INCH BY .5 INCH, FLOORBEAM 270 JUST AFT OF GEAR VIEW FINDER. INSTALLED NEW Z-ANGLE PER TR 53-20-08. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FLOORBEAM CORRODED 1 INCH BY .5 INCH, FLOORBEAM 270 JUST AFT OF GEAR VIEW FINDER. INSTALLED NEW Z-ANGLE PER TR 53-20-08. (M)