What was found
CLT - FOUND FUSELAGE SKIN CRACKED 1.125 INCH, AFT END OF E/E COOLING DUCT OUTLET. INSTALLED DOUBLER PER TR 53-30-04 AND DWG 65C33930. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FUSELAGE SKIN CRACKED 1.125 INCH, AFT END OF E/E COOLING DUCT OUTLET. INSTALLED DOUBLER PER TR 53-30-04 AND DWG 65C33930. (M)