What was found
PIT - FOUND CORROSION 1 INCH BY 2 INCH, LOWER LEFT AND BOTTOM FRAMES OF AFT VENTRAL DOOR. DEFECTIVE PART REPLACED WITH IDENTICAL PART NR PER DOUGLAS DWG 5910186 AND SRO J060114. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND CORROSION 1 INCH BY 2 INCH, LOWER LEFT AND BOTTOM FRAMES OF AFT VENTRAL DOOR. DEFECTIVE PART REPLACED WITH IDENTICAL PART NR PER DOUGLAS DWG 5910186 AND SRO J060114. (M)