What was found
PIT - FOUND BEAR STRAP HAD 1 INCH HOLE AFTER BLENDOUT, AT STATION 693 JUST TO RIGHT OF LONGERON 30. FABRICATE FILLER FROM .050 INCH 2024T-3 AND DOUBLER FROM .032 INCH 6AL-4V TITANIUM AND INSTALLED PER EA 54385. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND BEAR STRAP HAD 1 INCH HOLE AFTER BLENDOUT, AT STATION 693 JUST TO RIGHT OF LONGERON 30. FABRICATE FILLER FROM .050 INCH 2024T-3 AND DOUBLER FROM .032 INCH 6AL-4V TITANIUM AND INSTALLED PER EA 54385. (M)