What was found
CLT - FOUND FLOORBEAM CORRODED 2 INCHES BY 24 INCHES, STATION 345, BL 0 TO LBL 24. INSTALLED REPAIR T-CAP AND ANGLE PER TR 53-15-01. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FLOORBEAM CORRODED 2 INCHES BY 24 INCHES, STATION 345, BL 0 TO LBL 24. INSTALLED REPAIR T-CAP AND ANGLE PER TR 53-15-01. (M)