What was found
CLT - FOUND FLOORBEAM CORRODED 2 INCHES, STATION 344 AT BL 0, LBL 22. CORROSION LEVEL 1. INSTALLED FLOORBEAM TOP CAP PER SRM 51-70-12. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FLOORBEAM CORRODED 2 INCHES, STATION 344 AT BL 0, LBL 22. CORROSION LEVEL 1. INSTALLED FLOORBEAM TOP CAP PER SRM 51-70-12. (M)