CLT - FOUND DOOR Z-ANGLE CORRODED 6 FT BY 3 INCHES, STATION 947-1006, LBL 60, AFT ENTRY DOOR Z-ANGLE. INSTALLED NEW Z-ANGLE PER SRM 51-40-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND DOOR Z-ANGLE CORRODED 6 FT BY 3 INCHES, STATION 947-1006, LBL 60, AFT ENTRY DOOR Z-ANGLE. INSTALLED NEW Z-ANGLE PER SRM 51-40-02. (M)