What was found
CLT - FOUND FUSELAGE CRACKED, .120 INCH, STATION 947 AFT ENTRY DOOR LOWER HINGE CUTOUT. INSTALLED DOUBLER, FILLER AND TRIPLER PER SRM 53-30-03 FIG 34. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FUSELAGE CRACKED, .120 INCH, STATION 947 AFT ENTRY DOOR LOWER HINGE CUTOUT. INSTALLED DOUBLER, FILLER AND TRIPLER PER SRM 53-30-03 FIG 34. (M)