What was found
PIT - FOUND PANEL CRACKED .375 INCH PAST EXISTING STOP DRILL, KEEL BEAM PANEL BETWEEN WHEEL WELLS. INSTALLED TEMP REPAIR DOUBLER INCORPORATING BOTH CRACKED AREAS PER SRM 53-60-12 FIG 202/EA 53683D. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND PANEL CRACKED .375 INCH PAST EXISTING STOP DRILL, KEEL BEAM PANEL BETWEEN WHEEL WELLS. INSTALLED TEMP REPAIR DOUBLER INCORPORATING BOTH CRACKED AREAS PER SRM 53-60-12 FIG 202/EA 53683D. (M)