What was found
PIT - Q-6 - LONGERON 1 INCH LONG BY .75 INCH WIDE CORROSION; LEVEL 1; TASK NR C57-53300, STA 1287, LONGERON 27 RT, IN CENTER OF LONGERON. SPLICED IN NEW SECTION OF LONGERON; STA 1250-1301, 27 RT, PER SRM 53-02. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - Q-6 - LONGERON 1 INCH LONG BY .75 INCH WIDE CORROSION; LEVEL 1; TASK NR C57-53300, STA 1287, LONGERON 27 RT, IN CENTER OF LONGERON. SPLICED IN NEW SECTION OF LONGERON; STA 1250-1301, 27 RT, PER SRM 53-02. (X)