What was found
CLT - FOUND FLOORBEAM CORRODED, 1 INCH BY 8 INCH, BS 259 FLOORBEAM. INSTALLED DOUBLER AND NEW T-CAP PER TR 53-10-16 AND EA 67170. CORROSION LEVEL 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FLOORBEAM CORRODED, 1 INCH BY 8 INCH, BS 259 FLOORBEAM. INSTALLED DOUBLER AND NEW T-CAP PER TR 53-10-16 AND EA 67170. CORROSION LEVEL 2. (M)