What was found
CLT - FOUND FLOORBEAM CORRODED 1 INCH, STATION 312, LBBL 1 PLUS 8. FABRICATED ANGLES AND INSTALLED PER SRM 53-10-51. CORROSION LEVEL 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FLOORBEAM CORRODED 1 INCH, STATION 312, LBBL 1 PLUS 8. FABRICATED ANGLES AND INSTALLED PER SRM 53-10-51. CORROSION LEVEL 2. (M)