What was found
TPA - FOUND STRIP CRACKED .25 INCH, MAIN ENTRY DOOR, INNER STRUCTURE UPPER HINGE WEB. REPLACED STRAP PER SRM 51-10-2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TPA - FOUND STRIP CRACKED .25 INCH, MAIN ENTRY DOOR, INNER STRUCTURE UPPER HINGE WEB. REPLACED STRAP PER SRM 51-10-2. (M)