What was found
CLT - FOUND INTERCOSTAL CRACKED 1.5 INCH, STATION 660, STRINGER 14R. FABRICATED AND INSTALLED PER SRM 53-30-15. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND INTERCOSTAL CRACKED 1.5 INCH, STATION 660, STRINGER 14R. FABRICATED AND INSTALLED PER SRM 53-30-15. (M)