CLT - FOUND SEVERAL CRACKS .125 INCH OR LESS, INSIDE CHANNEL STRINGER 15L, BETWEEN STATION 520 AND 540. INSTALLED STRINGER REPAIR SECTION PER SRM 53-10-3. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND SEVERAL CRACKS .125 INCH OR LESS, INSIDE CHANNEL STRINGER 15L, BETWEEN STATION 520 AND 540. INSTALLED STRINGER REPAIR SECTION PER SRM 53-10-3. (M)