What was found
CLT - FOUND FRAME CRACKED .5 INCH, STATION 400, STRINGER 9L AT OVERHEAD BIN SUPPORT. INSTALLED DOUBLER PER SRM 53-10-14A. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FRAME CRACKED .5 INCH, STATION 400, STRINGER 9L AT OVERHEAD BIN SUPPORT. INSTALLED DOUBLER PER SRM 53-10-14A. (M)