CLT - FOUND FRAME CORRODED 1 INCH BY 3 INCHES, BS 767 BETWEEN STRINGER 26R AND 26L, LBL 0. INSTALLED REPAIR DOUBLER PER SRM 53-10-04, FIG 11. CORROSION LEVEL 1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FRAME CORRODED 1 INCH BY 3 INCHES, BS 767 BETWEEN STRINGER 26R AND 26L, LBL 0. INSTALLED REPAIR DOUBLER PER SRM 53-10-04, FIG 11. CORROSION LEVEL 1. (M)