What was found
PIT - FOUND CORROSION ON SUPPORT ANGLE, BETWEEN 312 AND 328, 11 INCHES LEFT OF BL 0. CORROSION LEVEL 2, TASK NR C53-107-02. INSTALLED FLOOR SUPPORT SECTION PER SRM 53-10-51. CORROSION LEVEL 2, TASK NR C53-107-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND CORROSION ON SUPPORT ANGLE, BETWEEN 312 AND 328, 11 INCHES LEFT OF BL 0. CORROSION LEVEL 2, TASK NR C53-107-02. INSTALLED FLOOR SUPPORT SECTION PER SRM 53-10-51. CORROSION LEVEL 2, TASK NR C53-107-02. (M)